WORKSHOP MANUAL VW-Porsche D-Jetronic ROBERT BOSCH CONTENTS How to use this Manual Fuel System Description . Air System Description. Electronic System Description... Functional Description . Wiring Harness Description Trouble-Shooting Chart..... Component Removal and Replacement . Test Chart. Ignition and Idle Adjustments . Service Parts List.. This manual is designed to assist you in the trouble-shooting and repair of vehicles, with the Robert Bosch D-Jetronic (EFI) System using mostly common workshop tools. You should understand this fuel injection system before you begin working on the vehicle. The Bosch Technical Instruction Booklet VDT-UBP 751/1B explains the D-Jetronic System in detail and will increase your understanding of this system. This will reduce repair times and facilitate the use of this Workshop Manual. 220 ROBERT BOSCH D-Jetronic HOW TO USE THIS MANUAL This manual is designed to instruct the technician unfamiliar with Robert Bosch fuel injection systems to locate faults in the system, isolate the component in- volved, and test the component for correct function. You will need a volt-ohm meter and a pressure gauge as well as the normal workshop tools. All measure- ‘ments are made at the terminals of the large plug at the end of the wiring harness after it is removed from the control unit. Most components of this system cannot be repaired and will have to be replaced once you have determined them detective. If you are already familiar with the Bosch D-JETRONIC system and can identify and locate all the components in the vehicle, you can go directly to the Trouble- Shooting Chart to track down the faulty component. Then test that component according to the Test Chart. If this fuel injection system is new to you, start with the Fuel, Air and Electronic System Descriptions, then read the section “Functional Description.” The section entitled “Component Removal and Replacement” will help you lo- cate each component in the vehicle. Then you can consult the Trouble-Shooting ‚Chart for the symptoms found on the vehicle in question. This will tell you what to check on the vehicle and direct you to the section of the Test Chart where the suspected component is checked for correct function. The last section of the manual, “Ignition and Idle Adjustments,” describes the timing and idle speed/mixture settings which should be checked after every repair and before the car is returned to the customer. Finally, a Service Parts List gives you the part numbers for seals, gaskets, plugs, etc., which you will need for replacement purposes D-Jetronic ROBERT BOSCH 221 FUEL SYSTEM DESCRIPTION Fuel is drawn from the tank via the fine filter © by an electric fuel pump © and forced into the pressure line ©. The ring main © which is connected to the pressure line routed in the frame provides the four injection valv ith fuel. The pressure regulator © maintains the pressure in the ring main at 2 kgf/cm? (28.5 psi). From here, the surplus fuel can flow back to the tank through the (pressureless) ine ©. The bypass return line coming from the fuel pump also leads into this line, 222 ROBERT BOSCH D-Jetronic AIR SYSTEM DESCRIPTION Four intake tubes © , which are connected to the via a bowden cable, Pedal at the mouth of the intake intake manifold @, supply the four cylinders with air. manifold. The intake manifold is connected to the A pressure switch @, a pressure sensor @ and the air filter @ by a rubber hose elbow ©. vacuum advance of the ignition distributor are also connected to the intake manifold, The idle-ir system is in the form of a bypass system in 'e switch reacts to the difference between the the intake manifold, It joins behind the throttle valve. in the intake manifold and the atmospheric Its functional cross section can be varied with the idle whilst the pressure sensor measures the actual adjustment screw © (idle adjustment). An auxiliary in the intake manifold (evacuated aneroids). line from the air filter via the auxiliary-ir device © There is a throttle valve, operated by the accelerator 10 the intake manifold forms the warm-up air system. effective cross section is varied, depending on the engine temperature, by the auxiliary-ir device. © Intake tubes @ Intake manifold © Pressure switch © Pressure sensor © Elbow © Air filter © (dle adjustment screw ® Auxilisry-air device (rotary valve) D-Jetronic ROBERT BOSCH 223 ELECTRONIC SYSTEM DESCRIPTION ® Key to schematic of system Information for the electronic control unit Fuel pump Information Signal Fuel filter Fuel tank A.B Pressure sensor Load condition ofthe Pressure regulator engine Solenoid-operated injection valve C.D Trigger contacts Engine speed, triggering Intake manifold of ignition distributor signal for start of injection Pressure sensor with full load enrichment ‘Auxiliary-air device with electrical heating in ‚mperature sensor! Correction of injected VW-Porsche 914. take manifold) quantity, dependent on air tomperature in the Cylinder he intake manifold Fuel distribution pipes to the injection valves Throttle valve switch with momentary enrichment ‘Temperature sensor Il Warm-up Ignition distributor with trigger contacts (cylinder head) ‘Thermo-time switch Throttle vaive switch Temporary enrichment and Electronic control unit (ECU) off during ‘Temperature sensor I in intake air di ibutor Temperature sensor Il in cylinder head Cold-start valve Idle adjustment screw From starting motor terminal 50 Start enrichment (cold-start simultaneously closed 224 ROBERT BOSCH D-Jetronic FUNCTIONAL DESCRIPTION Fuel is drawn from the tank © via the filter © by the This operational condition is characterized by a closed fuel pump ©, and foreed into the ring main throttle valve and increased engine speed. The throttle The pressure regulator ©, connected to the end of the valve switch (G) switches off the fuel supply during ‘ing main, limits the pressure of the fuel to 28.5 psi ‘overrun, when the vehicle speed is above 1 800 rev/min. {2 kat/em?). The solenoid-operated injection valves © If, during overrun, the speed drops to 1.250 rev/min are connected to the ring main via fuel distribution the fuel supply is switched on again so that a smooth pipes @. From the pressure regulator, surplus fuel can transition to idle operation is guaranteed. flow through a return line in the frame tunnel back To keep the electronic control unit as simple as to the tank. possible, and the cost of the unit as low as possibl ‘The bypass return line coming from the fuel pump leads fuel injection valves are parallel connected into ino ths in, There sa reif vale in the fel pump, of two (group 1 = cylinders 1 + 4; groups which comes into operation when the pressu group 2 = cylinders 2 + 3) Considerably above the nominal value a, for exampl Both fuel injection valves of one group inject fuel Could occur should the pressure regulator ©) develop a he same time. The injection valves of cylinders 1 and 3 defect. A non-return valve inthe pressure line connection inject fuel past the open intake valves, into the of the fue! pump prevents the pressure in the ring main Combustion chamber during the inlet stroke, whilst the from dropping immediately when the pump is switched injection valves of eylinders 2 and 4 inject onto the still off, The injection valves© are opened electrically in | closed intake valves while the exhaust gases are being ‘wo pairs (J and K) by the electronic control unit and, forced out, In this latter case the fuel is “stored” atthe duo to the fuel pressure, fuel i injected. The nozzle intake valves. duct of the injection valve is accurately calibrated. Since ‘The amount of air is controlled during vehicle operation the fuel pressure is kept constant, the injected fuel by the throtte valve in the intake manifold ‘quantity is dependent only on the length of time the When idling, the throttle vaive is completely closed. injection valve is kept open. The idle air can reach the intake tubes only via the This injection time is “computed” by the electronic bypass system in the intake manifold. The idle speed is control unit. The "data" or information processed by the adjusted by altering the cross section of the bypass electronics in the control unit comes from the individual system. For this purpose there is an adjusting screw and sensors on the engine, This is done in the following lock nut on the intake manifold. manner The adjustment must be carried out only with the engine ‘The moment when the fuel is injected is controlled by at operating temperature the distributor contacts (trigger contacts) 1 and It (Cand D) according to the position of the camshaft ‘These contacts are installed under the centrifugal advance by the auxiliary-air device (rotary valve). It alters the device in the distributor and are maintenance free. effective cross section of the auxil The injection duration (fuel quantity) is governed accordance with the oil temperature, The position of basically by two factors: by the engine speed and the the rotary valve i controlled by a bimgtal springwhich load condition of the engine. The engine speed is protrudes into the crankcase. At -30 °C (22 relayed to the control unit by the distributor ‘the rotary valve is open and at +80°C (122 °F) itis contacts | and Il. The load condition (part load or fully closed, full oad) is indicated by the pressure in the intake manifold. The prevailing pressure here is converted to an electrical impulse and also relayed to the control unit (A and B} by the pressure sensor ® which is connected to the intake manifold © by a hose, The electronic control unit processes this information and ives a signal for the injection valves to be opened for longer or shorter period of time (J and K). The ‘control unit thus allows more or less fuel to be passed through the solenoid-operated injection valves {depending on the engine toad and thee speed. This is how the “basic quantity of fu is determined. Inaddition to the “basic quantity of fuel”, a an accurately metered quantity of fuel is injected additionally (enrichment) when starting at low outside Temperatures, when the engine is warming-up and at full load, The starting enrichment of the air/fuel mixture is dependent on the engine temperature which is measured electrically by two temperature sensors, one in the ikease and the other on the cylinder head (E and F}. Starting enrichment may only take place when the starting motor is operated. The information as to when the starting motor is operating is relayed to the control unit vie a cable which is connected to terminal 50 of the starter solenoid switch. in relation to the basic quantity of fu impulses are relayed electrically to the fuel injection valves, The same principle applies during overrun (braking with the engine): in this case no fuel must be injected, D-Jetronic ROBERT BOSCH 225 WIRING HARNESS DESCRIPTION ‘The individual cables are marked with the corresponding cable number. These cable numbers are printed about 3/8" 10 3/4" from each cable end. Cable Number From To Cable Number 1 electronic control ur temperature sensor | 1 intake manifold) 2 not used 3 electronic control unit injection valve cyl. 1 3 4 electronic control unit injection valve cyl. 4 4 5 electronic control unit injection valve cyl. 2 5 6 ‘electronic control unit injection valve cyl. 3 6 7 electronic control unit pressure sensor 7 a electronic control unit pressure sensor a 9 electronic control unit throttle valve switch 9 10 electronic control unit pressure sensor 10 " electronic control unit ground (on crankcase) " 12 electronic control unit trigger contact in 2 ignition distributor 13 electronic control unit temperature sensor | 1B (intake manifold) 4 not used 15 electronic control unit pressure sensor 15 16 electronic control unit main relay terminal 87 6 (via plug housingT 1) 7 electronic control unit throttie valve switch 7 18 eleetronie control unit starting motor terminal 50 18 (via plug housing T 1) 19 electronic control unit Pump relay terminal 85 19 {via plug housing T 1) 20 electronic control unit throttie valve switch 20 a electronic control unit trigger contact in 2 ignition distributor 2 electronic control unit trigger contact in 2 Ignition distributor 2 electronic control unit temperature sensor II 23 {cylinder head) 2 electronic control unit main relay terminal 8724 (via plug housing T 1) 3 not used 26 injection valve cyl. 1 ground 26 2 injection valve cyl, 2 ground a 2B injection valve cyl. 3 round N on crankcase 2B 2 Injection valve cyl. 4 ground 2 30 throttle valve switch ground 30 terminal 14 a ccold:start valve starting motor terminal 50 31 {via plug housing T 1) 32 cold-start valve thermo-switch 32 a throttle valve switch ground on crankcase a {as from 8.71) 226 ROBERT BOSCH D-Jetronic 8 ® OY. | TM~). © Electric fuel pump © Solenoiteperated ction vane © To ignition switch terminal 16 (fuse box) @ Throttle valve switch with momentary enrichment Toone ermine 30 tgion uns wit wager conc Tı Printed-circuit board plug connection Electr sontrol unit/ECU Tz Cable connector ‘Temperature sensor | in intake manifold © Temperature sensor I! in cylinder head ® Cold-start valve Cables 18 and 31 from starting motor terminal 50 Pump relay D-Jetronic ROBERT BOSCH 227 TROUBLE-SHOOTING CHART [these et aut vanes same ponte sring mr. With engine warm, set dwell angl 1nd ignition point accurately according 10 instructions. Sufficient power? No vos ‘Check spark plugs, interference suppression resistors, distributor rotor, ignition cables, distributor cap, con- tact points, condenser and ignition co Allin order? Yes No [| Replace detective parts. ] Compression pressure and pressure Yes No Examine engine for mechanical faults. Clean or replace ter. Check if correctly Yes Throttle plate fully open at full throttle? ‘Adjust throttle valve cable ‘All hoses to pressure sensor and intake manifold connected correctly and air tight? Yes No (Check hoses and replace if necessary. ] With engine running, check fuel pressure. Nominal value: 2 ...2.2 kgf/cm? Replace defective parts (e.g. pressure regulator or clogged fuel filter). Check injection system. In order? Yes No Replace defective parts. I : With stroboscopic timing light check vacuum advance {in the case of ignition distributors with double Clean vacuum holes. Check if vacuum holes are com: ‘vacuum units also check retarded ignition) pletely clear when throttle valve is closed. If throttle All in order? valve fully or partly covers a hole, replace air throttle Yes No }— assembly, Check vacuum and vacuum hoses. I Let engine run at 2000 rev/min. Check voltages at terminal 15 of ignition coil and terminal 87 on main ‘and pump relays. Eliminate contact resistances. (Check battery ter- Al in order? minals and connections to battery and engine). Yes No [Check electronic control unit and pressure sensor 228 ROBERT BOSCH D-Jetronic Engine is cranked but does not start. (Tank still has sufficient fuel), ‘Start engine as follows: First fully depress accelerator pedal, then switch on ignition and oper- ate starting motor. During starting leave the accelerator pedal fully depressed; do not pump! Engine starts? No Yes Fuel pump must run about 1 ae when ignition is switched on. Pump fuse in order? (Listen for pump noise). Yes Replace fuse. No | u. ‚Check fuel pressure when starting. Examine fuel hoses for Use voltmeter to ascertain if voltage Nominal value: 2 to 2.2 kgf/cm? kinks. Check fuel fitter. present on fuel pump. First connect Replace if necessary. voltmeter, then switch on ignition, Yes No Read voltage within 1 sec, Voltage present? Yes No Replace fuel pump. I Check injection system In order? Ge i Connect voltmeter to pump relay Yes No | | meionunen. lace defective infor- and within 1 sec of switching on ignition, check voltage between terminals 85 and 86. Voltage present? ‘Check cables between Yes Pump and pump relay. Plug in strobosco timingpic light. Crank engine. Check for ignition spark. Remove plug from terminals 85 and Ya No ‘Completely check over the 86 of the pump relay. Use test leads ignition system (spark plugs, 10 connect terminal 85 to ground interference suppression and terminal 86 to 30/51 on the resistors, spark plug relay. holders, ignition cables, Relay pulls in? Check thermo-switch and cold-start valve. distributor rotor, distribu: Voltage on ter ial 877 Replace defective or leaking parts. Check tor cap, contact points, Yes No that the correct combination of thermo: condenser, ignition coil). switch, cold-start valve and control unit is installed. Replace electroniccontol] { Replace defective relay. unit, Engine flooded: Remove pump relay fuse, spark plugs and distributor rotor. Operate In exceptional cases, water in the fuel system can cause corrosive starter for 3 to 8 secs in order to pump damage to the fuel pump, injection valves, cold-startvlve and superfluous petrol out of the cylinders, Pressure regulator. Corroded parts must be replaced, Drain the tank Do not smoke! Danger of fire. of all fuel and clean out water and rust in the fuel lines. If the engine firesa couple of times when starting cold but then stops due to flooding, the thermo-time switch0 280 130 205 ‘can be fitted in place of the thermo-switch (circuit: see Service Parts List). D-Jetronic ROBERT BOSCH 229 Enquire from driver about his operation of the vehicle and whether it is used for local town journeys or for longer dis- tances, (ess TI —— Adjust engine valves with greatest possible precision and exactly to speci fication, Test compression loss. Engine must be absolutely cold. I ‘Set dwell angle, ignition point and ‘electrode gap with greatest accuracy to specification. Engine warm. Test injection system In order? Check fuel pressure lines and connections, In order? Yes No Check entire fuel system, injection valves, On vehicles with automatic transmission check setting of engine speed regulator and adjust if necessary, Replace defective component 230 ROBERT BOSCH D-Jetronic COMPONENT REMOVAL AND REPLACEMENT In order to facilitate work in the engine compartment, it is advisable to first remove the hood. Throttle valve switch The air filter must be removed before parts of the system can be removed. 914/4 and 914-1.7 Hold plugs on both sides when pulling them out, never ‘The throttle valve switch is fitted under the air throttle pull at the cable! assembly, When plugging-in on the individual components take care that the rubber caps are correctly pushed over the 914-20 plugs. ‘The throttle valve switch is installed on the side of the air throttle assembly. Pressure sensor Removal Removal 914/4 and 914-1.7 ‘The pressure sensor is installed in the R.H. side wall in Remove air filter. Unhook return spring for the throttle the engine compartment. On vehicles with air en- valve. Loosen bowden cable operating the throttle valve. richment during overrun, the vacuum limiter is installed Screw out the two fastening screws for the air throttle together with the pressure sensor. assembly (arrows) Pull off plug at pressure sensor. Pull off vacuum hose. Fully unscrew the three fastening 914-20 screws (one above, two below the pressure sensor). Remove pressure sensor. ‘Note for installation The protection sleeve on the fitting of a new pressure Adjustment sensor must only be removed immediately before USA model up to and including July 1971 pushing on the connecting hose as otherwise the evacuated aneroids may become contaminated. Pressure sensor must be positioned horizontally. Air throttle assembly removed: Connect meter between terminals 17 and 47. Push switch onto throttle shaft and tighten the two fastening screws slightly. Tum switch until the indicator needle of the tester moves from the “es” position to "0". Tum switch one graduation = 2° counterclockwise from this position and tighten. Finally, check setting by operating the throttle valve, D-Jetronic ROBERT BOSCH 231 Throttle valve switch 0 280 120 021 as from FD 323 Throttle valve switch 0 280 120 032 as from FD 321 Pressure regulator Loosen the fastening screws. Turn the switch in a clockwise direction until an inner stop is felt. Tighten ‘The pressure regulator is located to the left of the cyl. 1 the fastening screws. spark plug and is attached to a bracket. To remove it, clamp off the two fuel lines, open the Note: hose clamps and detach the fuel hoses. Hold the throttle valve in the idle position during Unscrew fastening nut, using a 17 mm open-end wrench adjustment. and remove pressure regulator. In cases of doubt, remove the plug from the throttle valve switch and with ohmmeter check continuity be- ‘tween terminals 14 and 17 when valve is closed. Reading should be “0” 2. On slightly opening valve, the instrument must indicate Adjusting pressure regulator: ‘The setting of the pressure regulator (and hence fuel pressure) influences the fuel consumption and the ‘exhaust gas composition quite considerably. For this reason, the setting should be altered only if the Prossure measured varies from the checking value of When installing, pay particular attention to the correct 2.0-2.2 kaf/em? (285-308 psi). positioning of the rubber sleeve (arrow). 914/4 and 914-17 Connect pressure gauge to the fitting between cylinders 1 and 2. 914-20 Remove start valve and carefully detach fuelline. Connect pressure gauge with T-piece to fuel ine to start valve, or remove pressure sensor and connect pressure gauge to fuel line fitting. 232 ROBERT BOSCH D-Jetronic Temperature sensor | (intake manifold) Remove rubber cap and 2-pole plug. Screw out tempera- ‘ure sensor using 13 mm open-end wrench. After in- stalling pull protective rubber cap carefully over plug housing. Start the engine and allow to idle. Loosen the lock nut at the pressure regulator and set the pressure to 2.0 + 0.05 kgf/cm? (28.5 + 0.7 psi) by means of the hexagon head screw. Afterwards, retighten the lock nut well. D-Jetronic ROBERT BOSCH 233 Temperature sensor Il Auxiliary-air device (cylinder head) Removal ‘The temperature sensor is screwed in below the intake Screw out the two fastening screws (arrow), Draw tube of eyl. 4 heating element connection cable out of plug coupling (arrow). Pull off both air hoses. Removal Check heating element: Resistance between connecting plug and auxiliary-air device housing: 125 + 1.0 Dat + 20° (68° Fl. When installing, first fit air hoses, then fasten valve 914-20 ‘Temperature sensor Il is located between the intake tubes. Thermo-switch When installing ensure that the rubber seal is correctly positioned. Insert the rubber seal in such a manner that ‘The thermo-switch is screwed into a fastening bracket the raised inscription faces outwards. below the start valve. Screw out thermo-switch with a 24 mm open-end wrench, 234 ROBERT BOSCH D-Jetronic Start valve Installation of the injection valves Push injection valve holder Push injection valve outer I zating bushing (large rubber ring) into its groove on injection valve body. Place injection valve inner Io cating bushing (rubber seal ring) on the injection valve nozzle. Carefully place injection valve in position and align, i.e. plug connection upwards. Tighten fastening nut @ wel ü Push fuel hose into injection valve connection and tighten hose clamp correctly. Injection valves When removing, it is advisable to proceed as follows: Loosen fastening nuts of both valves on one side. Check valves for correct functioning (spray test) and for Teaks. Replace defective valve ROBERT BOSCH 235 Fuel filter Fuel pump ‘The fuel filter and fuel pump are installed on the body- Remo 1p to and including July 1972 work on the right hand side, below and in front of the Remove heater air hose. Pinch off with clamps fuel hoses engine and are accessible only from below (raise vehicle). to pump. Pull off electric plug. Loosen both fastening screws with a 10 mm socket wrench and remove pump. Removal: Do not damage rubber-bonded metal bearings when up to and including July 1972 removing pump. as from August 1972 Remove right-hand heater air hose Pull off plug. As from August 1972 Loosen M6 fastening nuts on rubber-bonded metal bearings. Remove right-hand heater air hose. Pull off right-hand heating flaps control box from heat ‘exchanger (do not disconnect the heater control cable) Draw out filter in upward direction. Pinch off with clamps both fuel lines to the filter. Pull off hoses. Installation Replace filter every 20 000 km/12 000 miles When installing, pay attention to direction of flow (arrow on filter housing) ‘Take care not to damage the filter bead when inserting in the holder. 236 ROBERT BOSCH D-Jetronic Open hose clamps of pressure, return and suction lines at. fuel pump. Pinch off fuel hoses (suction line ” and return line Ignition distributor It is advisable to remove the distributor cap before removing thedistributor. Disconnect 3-pin plug from distributor. Pull the blade terminal from terminal 1 of the coil. Loosen screw on clamping bracket. ‘After the fuel pump has been installed, when connecting Roplace the trigger contacts: These are mounted on a the fuel lines make sure that they are on no account holder in the lower part of the distributor. interchanged! Loosen the two screws for the trigger contact holder on the (removed) distributor. S = Suction side Take out the holder. D = Pressure side R = Return line ee Bofore installing a now holder lubricate the sliding ‘Check hose connections for leaks and correct position- ing. Make sure that no fuel hose touches the heater air hose or the bodywork. D-Jetronic ROBERT BOSCH 237 TEST CHART ALL MEASUREMENTS ARE MADE ON THE TERMINALS OF THE DISCONNECTED WIRING HARNESS PLUG TO THE CONTROL UNIT (ECU) WITH IGNITION OFF UNLESS OTHER- WISE INDICATED. Voltage Supply OPERATE: Ignition. MEASURE: Voltage supply to the ECU. VALUE: 11-12.5 V between terminal 16 and system ground at terminal 11 of ECU plug. DEVIATION: No reading: open circuit in cable from main relay to ECU, main relay does not energize, ignition switch defective (check for voltage at terminals 86, 30/51 and 87 of relay). Check cable 16 connecting main relay and ECU. Check cable 11 to ground. Voltage below 11 V: Contact resistance in cable 16 or 11 or at relay contacts. Also check cable 24 for voltage supply as described above for cable 16. OPERATE: Starter. MEASURE: Voltage between terminal 50 of starter and ground. VALUE: 9-12V. DEVIATION: No reading, but starter operates: open circuit from starter terminal 50 to ECU (check cable 18). No reading, starter does not operate: ignition switch defective or open circuit in cable. Voltage below 9 V: Battery low or voltage drop in cable from ignition switch to starter terminal 50 (check cable). 238 ROBERT BOSCH D-Jetronic TEST CHART Pressure Sensor MEASURE: Resistance between pressure sensorwindingsand ground. VALUE: Infinite resistance (©) between ECU plug terminal 11 (ground) and terminals 7, 8, 10 and 15 in turn DEVIATION: Zero resistance (continuity): Short circuit to ground in windings or cable. If meter at ECU terminals shows @2 with plug removed from sensor, replace sensor. Check cables 7, 8,10 and 15 for short to ground. Resistance lower than ®() but not Of}: Damage to cable insulation. MEASURE: Resistance of primary windings. VALUE: About 900 between terminals 7 and 15 of ECU plug. DEVIATION: Resistance considerably lower: Damage to insulation. Pull plug out of sensor and if tester reads @, replace sensor. Resistance 00 (continuity): Short to ground, short in primary windings. Pull plug from sensor, if meter reads ©Q, replace sensor. Resistance considerable higher: High contact resistance (test plugs and cables). Resistance @: Open circuit. Bridge terminals 7 and 15 at pressure sensor plug. If tester at ECU wiring harness terminals 7 and 15 reads zero, replace pressure sensor; if 00, check cables. MEASURE: Resistance of secondary windings. VALUE: About 3502 between terminals 8 and 10 of ECU plug. DEVIATION: As above under “primary windings.” For resistance 0, bridge terminals 8 and 10 at the pressure sensor plug. Resistance considerably higher: High contact resistance (test plugs and cables). D-Jetronic ROBERT BOSCH 239 TEST CHART Throttle Valve Switch OPERATE: Depress accelerator slowly. MEASURE: Full load enrichment function. VALUE: Alternating reading @/00 with meter connected between terminal 9 and system ground at terminal 11 of ECU plug. DEVIATION: If only 00 reading is shown, replace throttle valve switch. OPERATE: Accelerator in idle position. MEASURE: Function of idle contacts. VALUE: 00 (continuity) between terminal 17 and system ground at terminal 11 of ECU plug. DEVIATION: Resistance © Q: throttle valve switch incorrectly adjusted. Adjust according to appropriate section in “Component Removal and Replacement.” Open circuit in cable (check cables). If direct reading at terminals 47 and 17 of throttle valve switch still gives infinite resistance (00), replace throttle valve switch. OPERATE: Accelerator slightly depressed. MEASURE: Function of idle contacts. VALUE: © between terminals 17 and 11 of ECU plug. DEVIATION: Resistance 00 (continuity): throttle valve switch in- correctly adjusted or short circuit in cables. Pull plug from throttle valve switch. If meter at ECU plug still reads 00, cable is defective. Otherwise adjust or replace throttle valve switch. 240 ROBERT BOSCH D-Jetronic TEST CHART Temperature Sensor| (intake manifold) MEASURE: Resistance of the temperature sensor. VALUE: About 3000 at 68°F between terminals 1 and 13 of ECU plug. At 14°F, 860-1200; at 68°F, 260-3400; at 122°F, 90-1302. DEVIATION: If meter reads 0, check sensor directly at plug. If sensor checks out OK, replace cables. If tester shows Of (con- tinuity) at sensor terminals, replace sensor. If meter reads ON, pull plug from sensor. If meter then reads ©, replace sensor. Otherwise replace cables. Temperature Sensor Il (cylinder head) MEASURE: Resistance of the temperature sensor. VALUE: About 2.5kN at 68°F between ECU plug terminals 11 (ground) and 23. At 14°F, 7-12k0; at 68°F, 2-3k; at 122°F, .68-1KQ. DEVIATION: As above for Temperature Sensor I. Trigger Contacts In Distributor OPERATE: Starter to turn engine over. MEASURE: Correct function of trigger contacts in distributor. VALUE: Alternating reading between @ and 00 with meter con- nected between terminal 12 and terminals 21 and 22 in turn. DEVIATION: If needle remains at © or 00, check terminals 12, 21 and 22 at the distributor. If terminals and cables to ECU are OK, replace trigger contacts. D-Jetronic ROBERT BOSCH 241 TEST CHART Injection Valves MEASURE: Resistance of coil windings in valves. VALUE: 2.40 at 68°F between system ground at ECU plug terminal 11 and terminals 3, 4, 5 and 6 in turn. DEVIATION: Resistance zero: short circuit in winding or cable. Pull plug out of injection valve; if meter at ECU plug shows 2, replace valve, otherwise replace wiring harness. Resistance ©: open circuit in winding or cable. Check cable for continuity. If OK, replace valve. Resistance over 30: check ground cable from injection valves to engine. Visual check of injection valves: check connections, check grey caps pointing to rear on cylinders 2 and 4, black caps towards front. Check that protective caps are pulled over plugs. 242 ROBERT BOSCH D-Jetronic TEST CHART Fuel Pump, Pressure Regulator and Relay OPERATE: Turn on ignition and bridge ECU plug terminal 19 to system ground at terminal 11 to energize relays and operate fuel pump. Connect pressure gauge as described in section “Component Removal and Replacement.” Gauge remains connected for all remaining test steps. MEASURE: Pressure in fuel line and function of pressure regulator. VALUE: 2.0—2.2 kgf/cm? (28.5—30.8 psi) DEVIATION: No pressure build-up (pump does not start): pull plug from pump and measure voltage at plug contacts. If 12 V, pump is defective. If 0 V, check pump relay. If relay is operating, then check cable from relay terminal 87 to pump. If cables are OK, relay is defective. If relay is not operating, check cable from main relay terminal 87 to pump relay terminal 86 or from pump relay terminal 85 to cable 19 of the wiring harness (in engine compartment) for continuity. If cables check OK, replace pump relay. Pressure above or below 28-30 psi: pressure regulator incorrectly adjusted; adjust as described in “Component Removal and Replacement.” If adjustment not possible, replace unit. D-Jetronic ROBERT BOSCH 243 TEST CHART Leakage In System OPERATE: Turn on ignition and briefly bridge terminals 19 and 11 of ECU plug to energize relays and operate fuel pump. MEASURE: Leaks in fuel system. VALUE: After removing terminal bridge, pressure may drop from nominal value back to .8 kgf/cm? (11.4 psi). After this, any further pressure drop must be very slow. DEVIATION: After removing bridge, pressure drops immediately to below 1 kfg/cm? (14.2 psi) or drops to zero: leak in sys- tem from fuel pump to pressure regulator. Check all hoses and connections and injection valves for leaks. Build up pressure several times during test as required. Injection Valve Leakage Perform this test only if valves are suspected of leakage, since injectors must be removed. OPERATE: Starter and energize one set of valves at a time by bridg- ing ECU plug terminal 16 and terminals 3, 4, 5 and 6 in turn. MEASURE: Visual inspection of spray pattern. DEVIATION: Check for leaks. The injector orifice may become wet, but no more than two drops should form on the valve per minute. 244 ROBERT BOSCH D-Jetronic TEST CHART Cold Start Valve And Thermo-Switch With engine temperature above 32-50°F. OPERATE: Starter. MEASURE: Function of thermo-switch. VALUE: Pressure reading on gauge should not drop perceptibly. DEVIATION: If pressure falls when starter is operated, thermo-switch is defective. OPERATE: Starter with thermo-switch grounded. MEASURE: Function of cold-start valve. VALUE: Pressure reading on gauge should drop while cold-start valve injects. DEVIATION: If pressure does not drop when starter is operated, check cable 31 from cold-start valve to starter terminal 50 for continuity. If cable OK, check cold-start valve winding resistance at contacts on valve: 4.20 at 68°F. With engine temperature below 32-50°F. OPERATE: Starter (thermo-switch connected normally). MEASURE: Function of thermo-switch. VALUE: Pressure reading on gauge should drop slowly. DEVIATION: If pressure does not drop, thermo-time switch or cold- start valve defective. Test cold-start valve as described above. D-Jetronic ROBERT BOSCH 245 TEST CHART Thermo-Time Switch Engine temperature above 23-41°F. OPERATE: Starter. MEASURE: Function of thermo-time switch. VALUE: Pressure reading on gauge should not drop perceptibly. DEVIATION: If pressure falls when starter is operated, thermo-time switch is defective. OPERATE: Starter with thermo-time switch terminal W grounded. MEASURE: Function of cold-start valve. VALUE: Pressure reading on gauge should drop while cold-start valve injects. DEVIATION: If pressure does not drop when starter is operated, check cable 31 from cold-start valve to starter terminal 50. If cable OK, check cold-start valve winding resistance at contacts on valve: 4.20 at 68°F. Engine temperature below 23-41°F. OPERATE: Starter (thermo-time switch connected normally). MEASURE: Function of thermo-time switch. VALUE: Pressure reading on gauge must drop. DEVIATION: If pressure does not drop, thermo-time switch or cold- start valve defective. Test cold-start valve as described above. END OF TEST. TURN OFF IGNITION AND REMOVE PRESSURE GAUGE. 246 ROBERT BOSCH D-Jetronic IGNITION AND IDLE ADJUSTMENTS Adjusting ignition ‘Adjusting engine idle speed For this adjustment, the engine must be at operating 27° BTDC = red notch temperature (at least 70° C/158° F). 5° BTDC = "lack notch (only up to and including July 1971) Air fi removed! Toc O mark (as from August 1972) ne ‘notch in cooling blower housing ‘The idle speed is set to 900 + 50 rev/min by altering the by-pass cross section with the idle adjustment screw Engine temperature: approx. 70° C (158° F) (arrow). Assembly setting: 5° BTOC Using a stroboscopic timing light seti point to 27° crankshaft BTDC at n = 3500 rev/mi {red notch). Vacuum unit closed off at ignition distributor. Important! The following points must be observed before starting the engine: sngine run without the battery 2. Never use a high speed battery charger as a starting A = notch in cooling blower housing aid, 27° = red notch = setting point at 3500 rev/min. 3. When using a high speed charger to charge the battery in the vehicle, the battery should be disconnected from the rest of the electrical system. ‘Starting the engine: Cold and warm e dopress accelerator pedal fully, and release, before switchingon igr ion. After testing the cold-start valve, the engine must be bled before starting up, ie. disconnect the brown cable from the main relay and then crank the engine briefly DJetronic ROBERT BOSCH 247 SERVICE PARTS LIST Designation Bosch Part Number End cover for control unit 2.285 506 000 Protective cap for potentiometer on electronic control unit 1350 508 002 Grip on 25-pole plug 1.282.386 001 2-pole plug housing only, for injection valves, temperature 1.284.485 002 sensors, cold-start valve, throttle valve switch and pressure switch Rubber cap for 2-pole plug 1.280 703001 3-pole plug housing only, on distributor 1 284.485 003 Rubber cap for 3-pole plug 1.280 703 002 4-pole plug housing for pressure sensor and throttle valve switch 1284485004 Rubber cap for 4-pole plug 1.280 703 093 Receptacles 2.8 mm (1/8 in) 1 284.478 003 Plug housing only, for pump relay (term. 85 and 86) 1 284 485 012 Receptacles for above 1901 355 891 Rubber ring for injection valve 1280 206 702 Rubber seal ring for injection valve 1280 206 704 Plug housing only, for fuel pump 1284 485 009 Rubber cap for plug 1280 703 005 248 ROBERT BOSCH D-Jetronic D-Jetronic ROBERT BOSCH 249